Automation Components Inc (ACI)


11638 products

Automation Components Inc (ACI)

TS-1102-WA-10-AA

Automation Components Inc (ACI)

TS-1103-WA-03-AB

Automation Components Inc (ACI)

TS-204-MH-10-AA

Automation Components Inc (ACI)

TS-2104-GH-10-AA

Automation Components Inc (ACI)

TS-2104-PH-10-AA

Automation Components Inc (ACI)

TS-3200-PD-10-AA

Automation Components Inc (ACI)

TSENSE

TSENSE - CO2 Sensor with Temperatur RH & Display TSENSE is an advanced and versatile 3 in 1 transmitter. Designed for installation in the air conditioned zon it measures CO2 concentratio temperature and humidity in the ambient air. The data is transmitted to a BMS system or stand-alone controller using industry standard output signals and communications protocol including BACnet?. TSENSE combines all the necessary elements for effective climate control in commercial office building hospital hotel schools and other facilitie allowing for a comfortable and healthy environment for the occupants. It is flexible in design and is suitable for use in many different energy efficient ventilation strategies. 0 to 10 VDC outputs based on 0?2000 pp 32-122° 0-95% RH. Relay On/Of based on 1000/900 ppm (CO2). Life expectancy based on 15 years (typical). Backlit LCD displays: CO2 (ppm Temperature (°F and Humidity (%RH). Touch display menu system Environmental conditions covered: Carbon Dioxid Temperatur and Relative Humidity.  The two part numbers are TSENSE (no display) and TSENSE-LCD (with display). Carbon Dioxide sensors or transmitters for HVAC Building Automation System or ANSI/ASHRAE Standard 62.1-2004.  Typical applications include: school office building auditorium gymnasium shopping mall theatre demand control ventilatio economizers. Combines CO Temperatur and Relative Humidity into one uni Bacnet or analog output User-friendly menu

Automation Components Inc (ACI)

TSENSE-LCD

TSENSE - CO2 Sensor with Temperatur RH & Display TSENSE is an advanced and versatile 3 in 1 transmitter. Designed for installation in the air conditioned zon it measures CO2 concentratio temperature and humidity in the ambient air. The data is transmitted to a BMS system or stand-alone controller using industry standard output signals and communications protocol including BACnet?. TSENSE combines all the necessary elements for effective climate control in commercial office building hospital hotel schools and other facilitie allowing for a comfortable and healthy environment for the occupants. It is flexible in design and is suitable for use in many different energy efficient ventilation strategies. 0 to 10 VDC outputs based on 0?2000 pp 32-122° 0-95% RH. Relay On/Of based on 1000/900 ppm (CO2). Life expectancy based on 15 years (typical). Backlit LCD displays: CO2 (ppm Temperature (°F and Humidity (%RH). Touch display menu system Environmental conditions covered: Carbon Dioxid Temperatur and Relative Humidity.  The two part numbers are TSENSE (no display) and TSENSE-LCD (with display). Carbon Dioxide sensors or transmitters for HVAC Building Automation System or ANSI/ASHRAE Standard 62.1-2004.  Typical applications include: school office building auditorium gymnasium shopping mall theatre demand control ventilatio economizers. Combines CO Temperatur and Relative Humidity into one uni Bacnet or analog output User-friendly menu

Automation Components Inc (ACI)

TTL-232R-3V3

Automation Components Inc (ACI)

TTL-232R-3V3-AJ