Honeywell


52102 products

Honeywell

V4944L1024

Two Stage Pressure Regulating Gas Valve, 1 1/4", 120Vac, 8.8"-11.5" Water Column High Fire Regulator Setpoints, 10" Water Column Factory Setting, 1.4"-4.2" Low Fire Regulator Setpoints, 1.4" Water Column Factory Setting, LP Gas, 310-1030 Cfh Capacity, 6 Second Maximum Valve Opening Time, 2 Second Maximum Valve CLosing Time, Straight Through, Non Offset, 1/8" Pilot Tapping, 1/2 Psi Pressure Rating, Upright Horizontal Mounting, Slow Opening, Two 5/16" Unf Bleed Tappings, -40-150 Degree Operating Temperature Range, Aluminum Body, 1/4" Spade Terminals with Three 30" Leadwires

Honeywell

V4944L1024/U

Honeywell

V4944N1011

Two Stage Pressure Regulating Gas Valve, 1", 120Vac, 3"-4.5" Water Column High Fire Regulator Setpoints, 3.5" Water Column Factory Setting, 0.8"-2" Low Fire Regulator Setpoints, 0.8" Water Column Factory Setting, Natural Gas, 300-1000 Cfh Capacity, 6 Second Maximum Valve Opening Time, 2 Second Maximum Valve CLosing Time, Straight Through, Non Offset, 1/8" Pilot Tapping, 1/2 Psi Pressure Rating, Upright Horizontal Mounting, Slow Opening, Two 5/16" Unf Bleed Tappings, -40-150 Degree Operating Temperature Range, Aluminum Body, 1/4" Spade Terminals with Three 30" Leadwires

Honeywell

V4944N1011/U

Honeywell

V4944N1029

Two Stage Pressure Regulating Gas Valve, 1 1/4", 120Vac, 3"-4.5" Water Column High Fire Regulator Setpoints, 3.5" Water Column Factory Setting, 0.8"-2" Low Fire Regulator Setpoints, 0.8" Water Column Factory Setting, Natural Gas, 480-1600 Cfh Capacity, 6 Second Maximum Valve Opening Time, 2 Second Maximum Valve CLosing Time, Straight Through, Non Offset, 1/8" Pilot Tapping, 1/2 Psi Pressure Rating, Upright Horizontal Mounting, Slow Opening, Two 5/16" Unf Bleed Tappings, -40-150 Degree Operating Temperature Range, Aluminum Body, 1/4" Spade Terminals with Three 30" Leadwires

Honeywell

V4944N1029/U

Honeywell

V4944N1037

Two Stage Pressure Regulating Gas Valve, 1 1/2", 120Vac, 3"-4.5" Water Column High Fire Regulator Setpoints, 3.5" Water Column Factory Setting, 0.8"-2" Low Fire Regulator Setpoints, 0.8" Water Column Factory Setting, Natural Gas, 780-2300 Cfh Capacity, 6 Second Maximum Valve Opening Time, 2 Second Maximum Valve CLosing Time, Straight Through, Non Offset, 1/8" Pilot Tapping, 1/2 Psi Pressure Rating, Upright Horizontal Mounting, Slow Opening, Two 5/16" Unf Bleed Tappings, -40-150 Degree Operating Temperature Range, Aluminum Body, 1/4" Spade Terminals with Three 30" Leadwires

Honeywell

V4944N1037/U

Honeywell

V4944N1045

Two Stage Pressure Regulating Gas Valve, 2", 120Vac, 3"-4.5" Water Column High Fire Regulator Setpoints, 3.5" Water Column Factory Setting, 0.8"-2" Low Fire Regulator Setpoints, 0.8" Water Column Factory Setting, Natural Gas, 870-3000 Cfh Capacity, 6 Second Maximum Valve Opening Time, 2 Second Maximum Valve CLosing Time, Straight Through, Non Offset, 1/8" Pilot Tapping, 1/2 Psi Pressure Rating, Upright Horizontal Mounting, Slow Opening, Two 5/16" Unf Bleed Tappings, -40-150 Degree Operating Temperature Range, Aluminum Body, 1/4" Spade Terminals with Three 30" Leadwires

Honeywell

V4944N1045/U