EP-8000-3

Electro Pneumatic Transducer, Low Volume ( Non Relay ) Output, 4-20 mA Input Range, 3-15 Psig Output Range

Johnson Controls

EP-8000-4

Electro Pneumatic Transducer, High Volume ( Relay ) Output, 4-20 mA Input Range, 3-15 Psig Output Range

Johnson Controls

EP2101S

Johnson Controls

EP2101S1

Johnson Controls

EP2110S

Johnson Controls

EP2120S

Johnson Controls

EP2120S1

Johnson Controls

EP2121S1

Johnson Controls

EPC2

electric to pneumatic transducer which converts an analog input signal to a proportional pneumatic outpu modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC* offers four selectable input ranges of 0 to 0 to 1 0 to 15 VDC and 0 to 20 mA. Output pressure ranges are jumper shunt selectable for 0 to 1 0 to 15 and 0 to 20 psi and adjustable in all ranges. A 0-5 VDC feedback signal indicating the resultant branch line pressur is also provided. This signal varies linearly with branch pressure range selected. EPC's are designed with electrical terminals on one end and pneumatic connections on the othe allowing for maximum convenience in wiring and tubing installation when panel mounted. The EPC is a constant bleed interface with branch exhaust response time determined by the bleed orifice size and pressure differentials. If power fails to the EP it will continue to bleed through the bleed orifice until branch pressure is zero psig. Three way mixing valve control Pilot positioner control Compressor stagin Chiller loading

Johnson Controls

EPC2G

electric to pneumatic transducer which converts an analog input signal to a proportional pneumatic outpu modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC* offers four selectable input ranges of 0 to 0 to 1 0 to 15 VDC and 0 to 20 mA. Output pressure ranges are jumper shunt selectable for 0 to 1 0 to 15 and 0 to 20 psi and adjustable in all ranges. A 0-5 VDC feedback signal indicating the resultant branch line pressur is also provided. This signal varies linearly with branch pressure range selected. EPC's are designed with electrical terminals on one end and pneumatic connections on the othe allowing for maximum convenience in wiring and tubing installation when panel mounted. The EPC is a constant bleed interface with branch exhaust response time determined by the bleed orifice size and pressure differentials. If power fails to the EP it will continue to bleed through the bleed orifice until branch pressure is zero psig. Three way mixing valve control Pilot positioner control Compressor stagin Chiller loading