|
|
Resideo
R24ED5007
|
Heat Sequencer, 24Vac Input Voltage, 1-160 Second Off Timing Delay (First,Second,Third, Fourth and Fifth Switch), 1-160 Second On Timing Delay (First,Second,Third, Fourth and Fifth Switch), Electric Heat Applications, Solder or Screw Type 1/4" Quick Connect Electrical Connections, Shock and Vibration Resistent, Mounts in any Position, 25 Amp Resistive Contact Rating, 14 Amp Inductive Contact Rating at 120Vac, Four On Timings
|
|
|
Resideo
R4222B1082
|
General Purpose Switching Relay, 120Vac Coil Rating, SPDT, Full Load Contact Ratings: 3 Amp @ 480Vac, 6 Amp @ 208/240/277Vac, 12 Amp @ 120Vac, Locker Rotor Contact Rating: 18 Amp @ 480Vac, 35 Amp @ 208/240/277 Vac, 60 Amp @ 120Vac, Resistive Contact Rating: 10 Amp @ 480Vac, 20.8 Amp @ 120/208/240/277Vac, Pilot Duty Ratings: Minimum 3 VA @ 24/120Vac & 480Vac, Maximum: 25 VA @ 24Vac, 125 VA @ 120/240Vac and 480Vac, Resistive: 3 Amp @ 277Vac, Powerpile: ( Normally Open Contacts Only ) 0.25 Amp @ 0.25-12Vdc, 1/4" Quick Connect Terminals, -20-150 Degree Temperature Rating
|
|
|
Resideo
R4222D1013
|
General Purpose Switching Relay, 120Vac Coil Rating, DPDT, Full Load Contact Ratings: 3 Amp @ 480Vac, 6 Amp @ 208/240/277Vac, 12 Amp @ 120Vac, Locker Rotor Contact Rating: 18 Amp @ 480Vac, 35 Amp @ 208/240/277 Vac, 60 Amp @ 120Vac, Resistive Contact Rating: 10 Amp @ 480Vac, 20.8 Amp @ 120/208/240/277Vac, Pilot Duty Ratings: Minimum 3 VA @ 24/120Vac & 480Vac, Maximum: 25 VA @ 24Vac, 125 VA @ 120/240Vac and 480Vac, Resistive: 3 Amp @ 277Vac, Powerpile: ( Normally Open Contacts Only ) 0.25 Amp @ 0.25-12Vdc, 1/4" Quick Connect Terminals, -20-150 Degree Temperature Rating
|
|
|
Resideo
R4222D1021
|
General Purpose Switching Relay, 208/240Vac Coil Rating, DPDT, Full Load Contact Ratings: 3 Amp @ 480Vac, 6 Amp @ 208/240/277Vac, 12 Amp @ 120Vac, Locker Rotor Contact Rating: 18 Amp @ 480Vac, 35 Amp @ 208/240/277 Vac, 60 Amp @ 120Vac, Resistive Contact Rating: 10 Amp @ 480Vac, 20.8 Amp @ 120/208/240/277Vac, Pilot Duty Ratings: Minimum 3 VA @ 24/120Vac & 480Vac, Maximum: 25 VA @ 24Vac, 125 VA @ 120/240Vac and 480Vac, Resistive: 3 Amp @ 277Vac, Powerpile: ( Normally Open Contacts Only ) 0.25 Amp @ 0.25-12Vdc, 1/4" Quick Connect Terminals, -20-150 Degree Temperature Rating
|
|
|
Resideo
R4222N1002
|
General Purpose Switching Relay, 120Vac Coil Rating, DPDT- Pilot Duty, Full Load Contact Ratings: 3 Amp @ 480Vac, 6 Amp @ 208/240/277Vac, 12 Amp @ 120Vac, Locker Rotor Contact Rating: 18 Amp @ 480Vac, 35 Amp @ 208/240/277 Vac, 60 Amp @ 120Vac, Resistive Contact Rating: 10 Amp @ 480Vac, 20.8 Amp @ 120/208/240/277Vac, Pilot Duty Ratings: Minimum 3 VA @ 24/120Vac & 480Vac, Maximum: 25 VA @ 24Vac, 125 VA @ 120/240Vac and 480Vac, Resistive: 3 Amp @ 277Vac, Powerpile: ( Normally Open Contacts Only ) 0.25 Amp @ 0.25-12Vdc, 1/4" Quick Connect Terminals, -20-150 Degree Temperature Rating
|
|
|
Resideo
R7284B1024
|
Interrupted Electronic Oil Primary, Electrical Connections: Burner Motor, Oil Valve, Ignition, Cad Cell, Limit, Thermostat and Alarm, 15 Second Safety Switch Timing, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Rating: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Can be used with both Hydronic and Forced Air SystemsJunction Box on Main Burner Mounting, -40-147 Degree Temperature Range
|
|
|
Resideo
R7284P1080
|
Safety Switch
|
|
|
Resideo
R7284U1004
|
Interrupted Electronic Oil Primary, Electrical Connections: Burner Motor, Oil Valve, Ignition, Cad Cell, Limit, Thermostat and Alarm, Settable 15/30 or 45 Second Safety Switch Timing, Selectable Valve and Blower Delays and Two Line LCD Display,Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Rating: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Can be used with both Hydronic and Forced Air SystemsJunction Box on Main Burner Mounting, -40-147 Degree Temperature Range
|
|
|
Resideo
R8182D1079
|
Combination Protectorelay and Hydronic Heating Controller, 120Vac, 45 Second Safety Switch Timing, 130-240 Degree High Limit Operating Range, 110-220 Degree Low Limit Operating Range, 10 Degree Fixed High Limit Differential, 10-25 Degree Adjustable Low Limit or Circulator, 1 1/2" Insulation Depth, Vertical Mount, 4.4 Amp @ 120Vac Full Load Electrical Rating, 26.4 Amp @ 120Vac Locked Rotar Electrical Rating, Includes Auxiliary ZC and ZR Terminals that may be used to provide Circulator Zone Control through an R845A, Also Includes Heat Conductive Compound and Vertical Case
|
|
|
Resideo
R8182H1070
|
Combination Protectorelay and Hydronic Heating Controller, 120Vac, 45 Second Safety Switch Timing, 130-240 Degree High Limit Operating Range, 110-220 Degree Low Limit Operating Range, 10 Degree Fixed High Limit Differential, 10-25 Degree Adjustable Low Limit or Circulator, 1 1/2" Insulation Depth, Junction Box Mount, 4.4 Amp @ 120Vac Full Load Electrical Rating, 26.4 Amp @ 120Vac Locked Rotar Electrical Rating, Includes Auxiliary ZC and ZR Terminals that may be used to provide Circulator Zone Control through an R845A, Also Includes Heat Conductive Compound and Vertical Case
|