Automation Components Inc (ACI)
A/CTA-250-VFD
|
A/CTA-250-VFD - The A/CTA-VFD Series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear and proportional 4 to 20 mA output signa which can be monitored by your Building Managemen DD or PLC controller. All A/CTA-VFD units have a true RMS output and have jumper selectable input ranges (except for the 0 to 5 Amp range). The A/CTA-VFD series current sensors are fast acting and extremely accurate from 1 to 100% of the Full Scale Output. All of the A/CTA-VFD series current sensors are factory calibrated using a NIST Traceable standard and shipped with the jumper placed in the largest jumper selectable range. They must be externally powered using a +12 to 30 VDC power supply. The A/CTA-250-VFD Series has jumpers for 0-10 0-20 and 0-250Amps. ACI analog current sensors or transmitters are designed for HVAC Building Automation or industrial systems. Typical applications include: VF building load and load trending equipment. Patented 35mm Din-rail mounting flange Jumper selectable ranges
|
|
|
Automation Components Inc (ACI)
A/CTA-5
|
A/CTA-5 - The A/CTA Series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear and proportional 4 to 20 mA output signa which can be monitored by your Building Managemen DD or PLC controller. The A/CTA Series current sensors are available in either an Average or True RMS output version. All of these sensors have jumper selectable input ranges except for the 0 to 5 Amp input range on the A/CTA-05 series sensors. The A/CTA series current sensors are fast acting and extremely accurate from 1 to 100% of the Full Scale Output. All of the A/CTA series current sensors are factory calibrated using a NIST Traceable standard and shipped with the jumper placed in the largest jumper selectable range. They must be externally powered using a +12 to 30 VDC power supply. The A/CTA-50 Series has jumpers for 0-1 0-2 and 0-50Amps. ACI analog current sensors or transmitters are designed for HVAC Building Automation or industrial systems. Typical applications include: VF building load and load trending equipment. Patented 35mm Din-rail mounting flange
|
|
|
Automation Components Inc (ACI)
A/CTA2-250
|
|
|
|
Automation Components Inc (ACI)
A/CTA2-250-RMS
|
|
|
|
Automation Components Inc (ACI)
A/CTA2-5
|
|
|
|
Automation Components Inc (ACI)
A/CTA2-50
|
|
|
|
Automation Components Inc (ACI)
A/CTA2-50-RMS
|
|
|
|
Automation Components Inc (ACI)
A/CTE-250
|
A/CTE-250 - The A/CTE series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear 0 to 5 output signa which can be monitored by your Building Managemen DD or PLC controller. In addition they offer jumper selectable input ranges. The A/CTE series current sensors are fast acting and extremely accurate from 2% or 5% up to 100% of the Full Scale Output depending on the model being ordered. All of the A/CTE series current sensors are factory calibrated using a NIST Traceable standard and shipped with the jumper placed on the largest jumper selectable range. The power for the A/CTE series current transmitters is induced from the conductor being monitored. This means that no external power supply is necessary for the installation of these sensors. The A/CTE-250 current transmitter has jumper selectable ranges of 0-1 0-2 and 0-50Amps. ACI analog current sensors or transmitters are designed for HVAC Building Automation or industrial systems. Typical applications include: VF building load and load trending equipment. Patented 35mm Din-rail mounting flange Jumper selectable ranges
|
|
|
Automation Components Inc (ACI)
A/CTE-50
|
A/CTE-50 - The A/CTE series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear 0 to 5 output signa which can be monitored by your Building Managemen DD or PLC controller. In addition they offer jumper selectable input ranges. The A/CTE series current sensors are fast acting and extremely accurate from 2% or 5% up to 100% of the Full Scale Output depending on the model being ordered. All of the A/CTE series current sensors are factory calibrated using a NIST Traceable standard and shipped with the jumper placed on the largest jumper selectable range. The power for the A/CTE series current transmitters is induced from the conductor being monitored. This means that no external power supply is necessary for the installation of these sensors. The A/CTE-250 current transmitter has jumper selectable ranges of 0-10 0-20 and 0-250Amps. ACI analog current sensors or transmitters are designed for HVAC Building Automation or industrial systems. Typical applications include: VF building load and load trending equipment. Patented 35mm Din-rail mounting flange Jumper selectable ranges
|
|
|
Automation Components Inc (ACI)
A/CTE2-150
|
|