Automation Components Inc (ACI)


11638 products

Automation Components Inc (ACI)

A/SCS2

2.5A SPLIT CURRENT SWITCH N/O

Automation Components Inc (ACI)

A/SCS2-L

Automation Components Inc (ACI)

A/SCSX2

1.5Trip 0-250a Split Core Snsr

Automation Components Inc (ACI)

A/SCTA-50-VFD

A/SCTA-50-VFD - The A/SCTA-VFD Series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear and proportional 4 to 20 mA output signa which can be monitored by your Building Managemen DD or PLC controller. All A/SCTA-VFD units have a true RMS output and have jumper selectable input ranges (except for the 0 to 5 Amp range). The A/SCTA-VFD is a split-core sensor making it ideal for retrofit applications. These current sensors are fast acting and extremely accurate from 1 to 100% of the Full Scale Output. All of the A/SCTA-VFD series current sensors are factory calibrated using a NIST Traceable standard and shipped with the jumper placed in the largest jumper selectable range. The A/SCTA-VFD series must be externally powered using a +12 to 30 VDC power supply. The A/SCTA-50-VFD Series has jumpers for 0-1 0-2 and 0-50Amps. ACI analog current sensors or transmitters are designed for HVAC Building Automation or industrial systems.  Typical applications include: VF building load and load trending equipment. Patented 35mm Din-rail mounting flange Jumper selectable ranges

Automation Components Inc (ACI)

A/SCTA2-200

ANALOG CURRENT SENSOR 4-20mA

Automation Components Inc (ACI)

A/SCTA2-5

Automation Components Inc (ACI)

A/SCTA2-50

4-20mA DinRail SplitCore Sensr

Automation Components Inc (ACI)

A/SCTA2-50-RMS

Automation Components Inc (ACI)

A/SCTE-250

A/SCTE-250 - The A/SCTE series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear 0 to 5 VDC output signa which can be monitored by your Building Managemen DD or PLC controller. In addition they offer jumper selectable input ranges. The A/SCTE series current sensors are fast acting and extremely accurate from 5% to 10% up to 100% of the FSO (Full Scale Output) depending on the model being ordered. They are factory calibrated using a NIST Traceable standard and shipped with the jumper placed in the largest jumper selectable range. The power for the A/SCTE series current transmitter is induced from the conductor being monitored. This means that no external power supply is necessary for the installation of these sensors. Since these units have a split-core desig they make an excellent choice for existing installations because you will not have to power down the unit and disconnect any wires during the installation process. The A/SCTE-250 current transmitter has jumper selectable ranges of 0-1 0-2 and 0-50Amps. ACI analog current sensors or transmitters are designed for HVAC Building Automation or industrial systems.  Typical applications include: VF building load and load trending equipment. Patented 35mm Din-rail mounting flange Jumper selectable ranges

Automation Components Inc (ACI)

A/SCTE-50

A/SCTE-50 - The A/SCTE series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear 0 to 5 VDC output signa which can be monitored by your Building Managemen DD or PLC controller. In addition they offer jumper selectable input ranges. The A/SCTE series current sensors are fast acting and extremely accurate from 5% to 10% up to 100% of the FSO (Full Scale Output) depending on the model being ordered. They are factory calibrated using a NIST Traceable standard and shipped with the jumper placed in the largest jumper selectable range. The power for the A/SCTE series current transmitter is induced from the conductor being monitored. This means that no external power supply is necessary for the installation of these sensors. Since these units have a split-core desig they make an excellent choice for existing installations because you will not have to power down the unit and disconnect any wires during the installation process. The A/SCTE-50 current transmitter has jumper selectable ranges of 0-10 0-20 and 0-250Amps. ACI analog current sensors or transmitters are designed for HVAC Building Automation or industrial systems.  Typical applications include: VF building load and load trending equipment. Patented 35mm Din-rail mounting flange Jumper selectable ranges