Automation Components Inc (ACI)


11638 products

Automation Components Inc (ACI)

EFP2FS

EFP2FS - The EFP converts a floating point signal into a proportional pneumatic signal ranging from 0-20psig.  It is designed with electrical terminals on one end and pneumatic connections on the othe allowing for maximum convenience in wiring and tubing installation when panel mounted.  The EFP is a constant bleed interface with branch exhaust response time determined by the bleed orifice and pressure differentials.  If power fails to the EF it will continue to bleed through the bleed orifice until branch pressure is zero psig.  The EFP2 incorporates two valves (one controls exhaust) and does not bleed air at set point.  Its branch exahust flow and response time are not limited by an internal restrictor and are similar to its load rate.  If power fails to the EFP branch line pressure remains constant if the branch line does not leak air.  The EFP2FS is a two valve fail safe model.  It's 3-way branch exhaust valve allows exhaust of branch line air on a power failure.  The EFP is covered by ACI's Two (2) Year Limited Warranty. Three way mixing valve control Pilot positioner control Compressor stagin Fan Vane control

Automation Components Inc (ACI)

EFP2G

Float.Pt.to Pneumatic W/feed.

Automation Components Inc (ACI)

EFP2GFS

Float.Pt.to Pneu/FailSf/gauge

Automation Components Inc (ACI)

EFPG

Automation Components Inc (ACI)

ENC1

Automation Components Inc (ACI)

EPC

EPC - The EPC* is an electric to pneumatic transducer which converts an analog input signal to a proportional pneumatic outpu modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC* offers four selectable input ranges of 0 to 0 to 1 0 to 15 VDC and 0 to 20 mA. Output pressure ranges are jumper shunt selectable for 0 to 1 0 to 15 and 0 to 20 psi and adjustable in all ranges. A 0-5 VDC feedback signal indicating the resultant branch line pressur is also provided.  EPC's are designed with electrical terminals on one end and pneumatic connections on the othe allowing for maximum convenience in wiring and tubing installation when panel mounted.  The EPC is covered by ACI's Two (2) Year Limited Warranty. Three way mixing valve control Pilot positioner control Compressor stagin Chiller loading

Automation Components Inc (ACI)

EPC2

EPC2 - The EPC* is an electric to pneumatic transducer which converts an analog input signal to a proportional pneumatic outpu modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC* offers four selectable input ranges of 0 to 0 to 1 0 to 15 VDC and 0 to 20 mA. Output pressure ranges are jumper shunt selectable for 0 to 1 0 to 15 and 0 to 20 psi and adjustable in all ranges. A 0-5 VDC feedback signal indicating the resultant branch line pressur is also provided. This signal varies linearly with branch pressure range selected. EPC's are designed with electrical terminals on one end and pneumatic connections on the othe allowing for maximum convenience in wiring and tubing installation when panel mounted. The EPC is a constant bleed interface with branch exhaust response time determined by the bleed orifice size and pressure differentials. If power fails to the EP it will continue to bleed through the bleed orifice until branch pressure is zero psig. Three way mixing valve control Pilot positioner control Compressor stagin Chiller loading

Automation Components Inc (ACI)

EPC2FS

EPC2FS - The EPC* is an electric to pneumatic transducer which converts an analog input signal to a proportional pneumatic outpu modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC* offers four selectable input ranges of 0 to 0 to 1 0 to 15 VDC and 0 to 20 mA. Output pressure ranges are jumper shunt selectable for 0 to 1 0 to 15 and 0 to 20 psi and adjustable in all ranges. A 0-5 VDC feedback signal indicating the resultant branch line pressur is also provided. This signal varies linearly with branch pressure range selected. EPC's are designed with electrical terminals on one end and pneumatic connections on the othe allowing for maximum convenience in wiring and tubing installation when panel mounted. The EPC is a constant bleed interface with branch exhaust response time determined by the bleed orifice size and pressure differentials. If power fails to the EP it will continue to bleed through the bleed orifice until branch pressure is zero psig. Three way mixing valve control Pilot positioner control Compressor stagin Chiller loading

Automation Components Inc (ACI)

EPC2G

EPC2G - The EPC* is an electric to pneumatic transducer which converts an analog input signal to a proportional pneumatic outpu modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC* offers four selectable input ranges of 0 to 0 to 1 0 to 15 VDC and 0 to 20 mA. Output pressure ranges are jumper shunt selectable for 0 to 1 0 to 15 and 0 to 20 psi and adjustable in all ranges. A 0-5 VDC feedback signal indicating the resultant branch line pressur is also provided. This signal varies linearly with branch pressure range selected. EPC's are designed with electrical terminals on one end and pneumatic connections on the othe allowing for maximum convenience in wiring and tubing installation when panel mounted. The EPC is a constant bleed interface with branch exhaust response time determined by the bleed orifice size and pressure differentials. If power fails to the EP it will continue to bleed through the bleed orifice until branch pressure is zero psig. Three way mixing valve control Pilot positioner control Compressor stagin Chiller loading

Automation Components Inc (ACI)

EPC2GB